Circuit Breaker Supplier

Datetime: 2025-06-18   Visit: waite to update

Yueqing Kangpa Electric Co., Ltd. was established in 2009, covering an area of 12,000 square meters.Our company is the electric and electronic expert. And we can offer more than 600 kinds of distributing and controlling system products.Kampa CREAT in 2010. It is specialized in producing Circuit breaker and Distribution box. It has ISO9001, 5S system and advantage technology equipment. 

Our company is the electric and electronic expert. And we can offer more than 600kinds of distributing and controlling system products. 

phone:+86 137 5778 6841

product description

Modle Case Circuit Breaker NSX-100N 3P

NSX series Moudle Case Circuit Breaker (MCCB) is mainly applied to the power cirucit of AC 50Hz, rated insulation voltage 750V, Rated operated voltage up to 690V, and Rated current up to 630A. It has the protect function against the damage of overload, short-circuit and under-voltage. This product conforms to Standard of IEC60947-2.

Specifications

ModleNSX100   NSX160   NSX250   NSX400 
Frame Current (A)100   160   250   400 
Number of Poles3 4 3 4 3 4 3 
Ultimate Breaking Capacity (Icu, kA)FN HFN HFN HFN
AC220/240V (kA)8590 1008590 1008590 1004085
AC380/415V (kA)3650 703650 703650 703650
Rated Insulation VoltageAC800V             
Rated Working VoltageAC690V             
Rated Current, Thermal Tripping, TMD, A63, 80, 100   80, 100, 125, 160   125, 160, 200, 250   – 
Rated Current, Electronic Tripping, MIC, A40, 100   40, 100, 160   100, 160, 250   250, 400 
Auxiliary, Alert, Fault AccessoriesOF/SD/SDE/SDX             
Shunt & Under Voltage CoilMX/MN             
Mechanical Life50000   40000   20000   15000 
Electric life30000   20000   10000   6000 

LC1D40 AC Contactors


 
LC1D40 AC Contactors is suitable for using in the circuits up to the rated voltage 660v,AC 50hz or 60hz,rated current up to 95A,for making ,breaking frequently starting &machine-interlocking device etc,it becomes the dalay contactor,mechanical interlocking contactor,star-delta starter.with the thermal relay,it is combined into the electromagnetic starter.

Specification

ModelRated working Rated heatAC3 capacity of three-phase squirrel-cage motor AC3(KW)     
 current (A) current220/230V380/400V415V440V500V600/690V
 AC3AC4(A)KWKWKWKWKWKW
LC1-D0993.5202.24445.55.5
LC1-D121252035.55.55.57.57.5
LC1-D18187.73247.5991010
LC1-D25258.5405.51111111515
LC1-D323212507.515151518.518.5
LC1-D404018.5601118.522222230
LC1-D50502480152225303033
LC1-D6565288018.53037373737
LC1-D808037125223745455545
LC1-D959544125254545455545
Number of the contact3P+NO        
 3P+NC        
 3P+(NO+NC)        
Matched auxiliry contactorLA1-DN02(2NC),LA1-DN11(1NO+1NC),LA1-DN20(2NO),LA1-DN22(2NO+2NC)        
 LA1-DN40(4NO),LA1-DN04(4NC),LA1-DN13(1NO+3NC),LA1-DN31(3NO+1NC)        
Matched time delay auxiliary contactTime delay after power on:LA2-DT0(0.1-3s),LA2-DT2(0.1-30s),LA2-DT4(10-180s)        
 Time delay after power off:LA3-DR0(0.1-3s),LA3-DR2(0.1-30s),LA3-DR4(10-180s)        
External dimensions & Installation dimensions 
×

Inquiry Form

Inquiry