DIN rail staircase timer with adjustable time delay, ideal for corridor lighting and energy-saving control.The Aist 8 is a DIN rail-mounted staircase timer switch, designed for automatic control of corridor lights, stairwell lamps, and ventilation systems. With an adjustable time delay setting, it automatically turns off lights after a preset period to save energy. Description: […]
DIN rail staircase timer with adjustable time delay, ideal for corridor lighting and energy-saving control.The Aist 8 is a DIN rail-mounted staircase timer switch, designed for automatic control of corridor lights, stairwell lamps, and ventilation systems. With an adjustable time delay setting, it automatically turns off lights after a preset period to save energy.
Description:
– Staircase time switch, electro-mechcanical
– 4 conductor with floor lighting connection
– 3 conductor without floor lighting (no longer permitted for new systems)
– Retriggerable
– No closed-circuit current consumption
– Toggle switch for permanent light ON
– Reliable due to synchronous motor drive
– Simplest possible time setting and direct delay time readout on absolutescale
– Precision mechanics and therefore exact switching period
– Very low sensitivity to interference
Technical Data:
| Operating voltage | 230 V AC |
| Frequency | 50 Hz |
| Width | 1 module |
| Installation type | DIN rail |
| Stand-by consumption | 0 W |
| Glow lamp load | 50mA |
| Setting range time | 1 – 7 min |
| Type of connection | 3-/4-conductors |
| 3/4-way conductors | Yes |
| Secondary switching | After 30 s |
| Type of contact | NO contact |
| Opening width | > 3 mm |
| Switching output | Not potential-free (230 V) |
| Incandescent/halogen lamp load | 2300 W |
| Fluorescent lamp load (conventional)lead-lag circuit | 2300 VA |
| Fluorescent lamp load (conventional) parallel-corrected | 1300 VA 70 uF |
| energy saving lamps | 150 W |
| LED lamp | < 2 W = 30 W or > 2 W < 8 W = 90 W |
| Fluorescent lamp load (electronic ballast) | 600 W |
| Fluorescent lamp load (conventional)series-corrected | 2300 VA |
| Switching capacity | 6 A (at 230 V AC, cos φ = 0.3), 16 A (at 230 V AC, cos φ = 1) |
| Switch for permanent light | Toggle switch |
| Housing and insulation material | High-temperature resistant, self-extinguishing thermoplastic |
| Ambient temperature | -10 °C … +50 °C |
| Protection class | II in accordance with EN 60 730-1 |
| Type of protection | IP 20 |

Circuit Breaker vs Contactor vs Overload Relay: What Is the Difference?
Quick Answer A circuit breaker, contactor, and overload relay are often installed together in...
Date:2026-06-09[5 minutes] Let you know what is circuit breaker for electrical equipment!
On "Why do circuit breakers close", "Solutions for circuit breakers failure", "What is spring st...
Date:2025-06-18