Application GV2 series motor protection circuit breakers are mainly used for the overload and short circuit protection of the motor in AC 50/60HZ,up to 660V,0.1-80A power circuit,as a full voltage starter to start and cut off the motor,under the AC3 load or for the overload and short circuit protection of the circuit and power equipment […]
Application
GV2 series motor protection circuit breakers are mainly used for the overload and short circuit protection of the motor in AC 50/60HZ,up to 660V,0.1-80A power circuit,as a full voltage starter to start and cut off the motor,under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network.
Specification
| Type | Rated standard power of 3-phase motors 50/60HZ in category AC-3 | Setting range(A) | |||||
| 220V | 380V | 415V | 440V | 500V | 660V | ||
| KW | KW | KW | KW | KW | KW | ||
| GV2-M01 | — | — | — | — | — | — | 0.1-0.16 |
| GV2-M02 | — | — | — | — | — | — | 0.16-0.25 |
| GV2-M03 | — | — | — | — | — | — | 0.25-0.4 |
| GV2-M04 | — | — | — | — | — | 0.37 | 0.4-0.63 |
| GV2-M05 | — | — | — | 0.37 | 0.37 | 0.55 | 0.63-1.0 |
| GV2-M06 | — | 0.37 | — | 0.55 | 0.75 | 1.1 | 1.0-1.6 |
| GV2-M07 | 0.37 | 0.75 | 0.75 | 1.1 | 1.1 | 1.5 | 1.6-2.5 |
| GV2-M08 | 0.75 | 1.5 | 1.5 | 1.5 | 2.2 | 3 | 2.5-4.0 |
| GV2-M10 | 1.1 | 2.2 | 2.2 | 3 | 3.7 | 4 | 4-6.3 |
| GV2-M14 | 2.2 | 4 | 4 | 4 | 5.5 | 7.5 | 6.0-10.0 |
| GV2-M16 | 3 | 5.5 | 5.5 | 7.5 | 7.5 | 9 | 9.0-14.0 |
| GV2-M20 | 4 | 7.5 | 9 | 9 | 9 | 11 | 13.0-18.0 |
| GV2-M21 | 5.5 | 11 | 11 | 11 | 11 | 15 | 17.0-23.0 |
| GV2-M22 | 5.5 | 11 | 11 | 11 | 15 | 18.5 | 20.0-25.0 |
| GV2-M32 | 7.5 | 15 | 15 | 15 | 18.5 | 26 | 24.0-32.0 |
| GV3-M06 | — | 0.37 | — | 0.55 | 0.75 | 1.1 | 1.0-1.6 |
| GV3-M07 | 0.37 | 0.75 | 1.1 | 1.1 | 1.1 | 1.5 | 1.6-2.5 |
| GV3-M08 | 0.75 | 1.5 | 1.5 | 1.5 | 2.2 | 3 | 2.5-4.0 |
| GV3-M10 | 1.1 | 2.2 | 2.2 | 3 | 3.7 | 4 | 4.0-6.0 |
| GV3-M14 | 2.2 | 4 | 4 | 4 | 5.5 | 7.5 | 6.0-10.0 |
| GV3-M20 | 4 | 7.5 | 7.5 | 7.5 | 10 | 11 | 10.0-16.0 |
| GV3-M25 | 5.5 | 11 | 11 | 11 | 15 | 18.5 | 16.0-25.0 |
| GV3-M40 | 11 | 18.5 | 22 | 22 | 25 | 33 | 25.0-40.0 |
| GV3-M63 | 15 | 30 | 33 | 33 | 40 | 55 | 40.0-63.0 |
| GV3-M80 | 22 | 40 | 45 | 45 | 55 | 63 | 56.0-80.0 |
How Do ACBs Improve Safety, Efficiency, and Reliability in Modern Applications?
Why Are Air Circuit Breakers Crucial in Modern Electrical Systems? In today's rapidly evolvin...
Date:2025-09-16Why Are Air Circuit Breakers Essential for Safe and Reliable Oil and Gas Operations?
Introduction In the oil and gas industry, the reliability of power distribution systems is di...
Date:2025-10-11