| Contact Data | |
| Contact Ratings | 1Z,1H,1D |
| Contact Resistance | 30mΩ (1A 6VDC) |
| Contact capacity | 40A 250VAC 2HP 250VAC |
| Characteristics | |
| Insulation Resistance | 1000MΩ, 500VDC |
| Dielectric Strength | Between coil and contacts 2500VAC 1minute |
| Between open contacts 1200VAC 1minute | |
| Operate Time | 25ms / 25ms |
| Terminal Type | Screw |
| Coil power | |
| Nominal Coil Power | DC2.0W AC2.5VA |
Specification
| Nominal Voltage VDC | Pull-in Voltage | Release Voltage | Coil ResistanceΩ:±10% | Nominal Voltage VAC | Pull-in Voltage | Release Voltage | Coil ResistanceΩ:±10% |
| VDC | VDC | VDC | VDC | ||||
| 6 | 4.2 | 0.6 | 30 | 6 | 4.8 | 1.8 | 14.4 |
| 12 | 8.4 | 1.2 | 130 | 12 | 9.6 | 3.6 | 57 |
| 24 | 16.8 | 2.4 | 450 | 24 | 19.2 | 7.2 | 250 |
| 48 | 33.6 | 4.8 | 1820 | 48 | 38.4 | 14.4 | 921 |
| 60 | 42 | 6 | 2800 | 110 | 88 | 36 | 5000 |
| 110 | 88 | 11 | 9650 | 220/240 | 176 | 72 | 18000 |