Description1、Circuit will be cut off for overvoltage and undervoltage of the single phase circuit. It will automatic reset the connectingcircuit after the voltage recovery of single-phase circuit and delay of time without manual operation.2、Circuit protection will produce no malfunction ofr transient of temporary overvoltage, which can avoid voltage instability.3、Protection device will not be damaged for […]
Description
1、Circuit will be cut off for overvoltage and undervoltage of the single phase circuit. It will automatic reset the connecting
circuit after the voltage recovery of single-phase circuit and delay of time without manual operation.
2、Circuit protection will produce no malfunction ofr transient of temporary overvoltage, which can avoid voltage instability.
3、Protection device will not be damaged for circuit disconnection of protection device or sudden power recovery after sudden power
failure carused by weak jonits.
4、Protection deveice will not be damaged for the maximum overvoltage of circuit fault
Specification
Rated voltage :230V
Rated frequency:50/60Hz
Rate current:1A-100A adjustable (default 63A)
Under-voltge action cut-off value: 100V-210V adjustable(defait 170V)
over-voltage action cut-off value: 230V-300V adjustable (default 270V)
Power recovery delay after power failure:5s
Range of time delay: 1s-300s adjustable (default 30s)
Electrical machinery life-span:minimum 50000 times
Exterior dimension:82x35x65mm
Overvoltge and undervoltage restore value is 5V of the set value and overcurrent restore value is 1A less than set value
Rated limit overcurrent:40,63A,80A,100A
| Model number | AVP-63 / AVP-40 |
| Rated voltage | 220VAC 50HZ or 120VAC 50HZ |
| Rated current | 1A-40A adjustable(40A) 1A-63A adjustable(63A ) |
| Over-voltage action cut-off value | 240V-300V adjustable(default 270V )130-160V adjustable(default 160V ) |
| Under-voltge action cut-off value | 140-210V adjustable(default 170V ) 70-110V adjustable(default 90V ) |
| Overcurrent action cut -off value | 63A 1A-63A can be set (default 63A) 40A: 1A-40A can be set (default 40A) |
| Boot delay time | 1s-600s adjustable(defauIt 5s) |
| Own Power consumption | ≤2W |
| Electrical mechanical life | ≥100,000 times |
| Working environment | Temperature: -5⁰C~+40⁰C Humidity:<90% Altitude:≤2000 m |